Anesthesia Machine

MT350

Advanced configuration with large-screen waveforms and loops

The MT350 steps up from the entry platform with an 8.4-inch screen and adds P-V, P-Flow and V-Flow loop graphics, so waveforms, loops and measured values share one display. PRVC and SIMV-PRVC are available as options and can be enabled later as departmental needs grow. ACGO, a rotary knob and an integrated heated CO₂ absorber circuit come as standard, along with two drawers, a 30 kg top shelf and at least 1.5 hours of battery backup.

An 8.4-inch TFT touchscreen with rotary knob, waveforms and loops on one screen
P-V, P-Flow and V-Flow loops, with an optional CO₂ loop
Optional PRVC and SIMV-PRVC (pressure-regulated volume control)
Integrated heated CO₂ circuit, autoclavable at 134℃
Twin Selectatec vaporizer positions, self-compensating with no annual recalibration
Two drawers as standard and at least 1.5 hours of battery runtime
Features

Features & Structure

Ventilation & monitoring

  • An 8.4-inch TFT touchscreen with rotary knob, showing ventilation settings and measured data on one screen
  • Live pressure, flow and tidal volume waveforms with P-V, P-Flow and V-Flow loops
  • Standard modes: VCV, PCV, SIMV-V, SIMV-P, SPONT/PSV, Sigh, Standby and Manual
  • PRVC and SIMV-PRVC can be enabled as options, upgrading to pressure-regulated volume control when needed
  • VCV/PCV backup takes over automatically when gas or power supply fails
  • Tidal volume 20–1600 mL (10 mL optional), covering adults down to infants

Integrated breathing circuit

  • Front-end variable orifice flow sensor that stays linear at low flows
  • Integrated heating at 35℃ (±2℃) suppresses condensation in the circuit
  • The circuit is autoclavable at 134℃ and includes an integrated bypass
  • Strips down, cleans and disinfects without any special tools
  • Adult bellows 1600 mL with a 1500 mL soda lime canister

Gas delivery & vaporizers

  • A 4/5-tube flowmeter supports two- or three-gas configurations at 0–10 L/min per gas
  • Auxiliary O₂ flowmeter 0–15 L/min (optional) for spontaneous breathing or transport oxygen
  • ACGO delivered as standard, with O₂ flush at 25–75 L/min
  • Twin Selectatec vaporizer positions for sevoflurane, isoflurane and halothane
  • Vaporizers self-compensate for pressure, temperature and flow, with no annual recalibration
  • Independent active scavenging (AGSS) reduces anesthetic gas pollution in the OR

Structure & handling

  • Two drawers as standard, expandable to three, each rated for 5 kg
  • Top shelf 230 × 460 mm with 30 kg capacity and LED lighting
  • All four casters have independent brakes for stable transport and positioning
  • Built-in Li-ion battery 13.4 VDC / 2600 mAh for at least 1.5 hours
  • Two auxiliary power sockets for monitors or infusion devices