Anesthesia Machine

MT400

A mature platform, stable and reliable

The MT400 pairs a 10.4-inch touchscreen (1920 × 600) with waveforms, three loop graphics and 24-hour trends on a single display. PRVC and SIMV-PRVC are standard, tidal volume starts at 10 mL and the pressure limit spans 5–99 cmH₂O, covering infants through adults. Three auxiliary power sockets make it easy to add monitors and infusion devices.

A 10.4-inch TFT touchscreen (1920 × 600) with rotary knob
PRVC and SIMV-PRVC as standard (pressure-regulated volume control)
Waveforms, three loop graphics and 24-hour trend review
Tidal volume 10–1600 mL with a 5–99 cmH₂O pressure limit
Integrated heated CO₂ circuit, autoclavable at 134℃
Three auxiliary power sockets and at least 1.5 hours of battery runtime
Features

Features & Structure

Ventilation & monitoring

  • A 10.4-inch TFT touchscreen (1920 × 600) with rotary knob, parameters and waveforms clearly on one screen
  • Live pressure, flow and tidal volume waveforms with P-V, P-Flow and V-Flow loops
  • PRVC and SIMV-PRVC come standard — no need to add them as options
  • 24-hour trend review with switchable numeric and graphic trends
  • Tidal volume 10–1600 mL and a 5–99 cmH₂O pressure limit, from infants to adults
  • VCV/PCV backup takes over automatically when gas or power supply fails

Integrated breathing circuit

  • Front-end variable orifice flow sensor that stays linear at low flows
  • Integrated heating at 35℃ (±2℃) suppresses condensation in the circuit
  • The circuit is autoclavable at 134℃ and includes an integrated bypass
  • Strips down, cleans and disinfects without any special tools
  • Adult bellows 1600 mL with a 1500 mL soda lime canister

Gas delivery & vaporizers

  • O₂, N₂O and Air inlets, 0–10 L/min each
  • Auxiliary O₂ flowmeter 0–15 L/min (optional) for spontaneous breathing or transport oxygen
  • ACGO delivered as standard, with O₂ flush at 25–75 L/min
  • Twin Selectatec vaporizer positions for sevoflurane, isoflurane and halothane
  • Vaporizers self-compensate for pressure, temperature and flow, with no annual recalibration
  • Independent active scavenging (AGSS) reduces anesthetic gas pollution in the OR

Structure & handling

  • Two drawers as standard, expandable to three, each rated for 5 kg
  • Top shelf 230 × 460 mm with 30 kg capacity and LED lighting
  • All four casters have independent brakes for stable transport and positioning
  • Built-in Li-ion battery 13.4 VDC / 2600 mAh for at least 1.5 hours
  • Three auxiliary power sockets for monitors or infusion devices